Conditioned Power Center 1 CPC Series Conditioned Power Center RoHS Compliant
Conditioned Power Center 10 2.6 Conformance with Applicable Laws and Regulations This equipment must be installed and used in accordance with all appl
Conditioned Power Center 11 Welcome to the world of conditioned power. Electrical power users from around the world benefit from the use of clean, qua
Conditioned Power Center 12 Section 3 - Product Overview 3.2 Standard Features These include a “power on “ LED, TVSS Fault LEDs (one per phase), a loc
Conditioned Power Center 13 Section 3 - Product Overview complete monitoring of three phase voltages, currents, phase angles, power factor, demand, en
Conditioned Power Center 14 Section 4 - Preparation IMPORTANT ! Each unit is fully inspected and tested prior to leaving the factory. CPC series pro
Conditioned Power Center 15 Step 2 - A packing block assembly rests on top of the power conditioner to secure it tightly inside the packing crate. Re
Conditioned Power Center 16 Section 4 - Preparation Figure D - Shipping Crate Disassembly - 10 to 20 kVA Figure E—Shipping Crate Disassembl
Conditioned Power Center 17 Section 5 - Installation 5.1 Location For best performance, the CPC series should be installed within fifty (50) wire feet
Conditioned Power Center 18 5.3 Outer Panel Removal The side panels, the back panel, the top panel and the front panel have all been designed for easy
Conditioned Power Center 19 5.5.2 Programmable Circuit Breakers Before beginning installation, check the tag on the circuit breaker. The power condit
Conditioned Power Center 2 SM5505 - March 1, 2006—Rev. A
Conditioned Power Center 20 Section 5 - Installation Transformers are designed to meet a variety of requirements. Some locations (Europe, for example
Conditioned Power Center 21 Section 5 - Installation 5.6.2 Output Voltage Fine Adjustment The transformer secondary of the power conditioners is a 5 w
Conditioned Power Center 22 Specific locations for connecting the input and output safety ground conductors are discussed in Sections 5.9 and 5.10 tha
Conditioned Power Center 23 5.9 Input Power Connections The three-phase input connection is made at the lugs marked L1, L2, and L3 directly on the mai
Conditioned Power Center 24 Section 6 - Operation 6.1 Restoring For Service When wiring connections have been completed (or after maintenance or repai
Conditioned Power Center 25 Section 6 - Operation (NOTE: Under "no load" conditions, the transformer in the power conditioner will "ste
Conditioned Power Center 26 Section 7 - Options 7.1 Passive Harmonic Filter The passive harmonic filter package is located below the transformer secon
Conditioned Power Center 27 Section 7 - Options 7.4 Phase Loss/Low Voltage Detection and Protection When equipped with the power management option, th
Conditioned Power Center 28 Section 7 - Options 7.7 SEMI S2-0200 Certification For use in semiconductor fabrication applications, the manufacturer of
Conditioned Power Center 29 Section 7 - Options activated by the closure of an interlock switch or EMO button, provides a DC voltage to the over-volta
Conditioned Power Center 3 Caution Notice...
Conditioned Power Center 30 Section 8 - Troubleshooting/Maintenance 8.1 Conditions Requiring Troubleshooting Four conditions may occur, which require
Conditioned Power Center 31 Section 8 - Troubleshooting/Maintenance Prior to performing maintenance of any kind, lockout and tagout the electrical pow
Conditioned Power Center 32 Section 8 - Troubleshooting/Maintenance 8.1.4 Harmonic Filter Circuit Breaker Trips Out If equipped with a harmonic filter
Conditioned Power Center 33 Section 9 - Service and Support 9.1 Technical and Service Assistance In North and South America, the manufacturer offers t
Conditioned Power Center 34 Section 10 - Specifications 10.1 CPC Series Schematic A4—Page 35 B3—Page 36
Conditioned Power Center 35 Section 10 - Specifications 10.2 GPI Series 2000 Standard EMO C4—Page 34
Conditioned Power Center 36 Section 10 - Specifications 10.3 GPI Series 2000 Semi S2 EMO C4—Page 34
Conditioned Power Center 37 Section 10 - Specifications 10.4 Output Voltage Fine Adjustment TRANSFORMER SECONDARY Nominal +5% -5% Nom
Conditioned Power Center 38 Document Revision History Part # Title Rev. Letter Rel. Date Next Rev. Leve l SM5505 Conditioned Rev
Conditioned Power Center 39 ETA Systems 1450 Lakeside Drive Waukegan, IL 60085 (800) 321-6699 Phone: (330) 677-4424 - Fax: (330) 677-4471 http
Conditioned Power Center 4 Section 8 - Troubleshooting/Maintenance 8.1 Troubleshooting Conditions ...
Conditioned Power Center 5 P L E A S E ! For maximum safety, reliability, and user satisfaction, please read all of the follo
Conditioned Power Center 6 This manual describes the installation, connection, adjustment and operation of electrically powered equipment. For your c